2. Standard Configuration of Radiography & Fluoroscopy Digital X ray machine System |
No. |
Item |
Quantity |
1 |
Remote console (with touch screen control) |
1 set |
2 |
high-voltage generator |
1 set |
3 |
Toshiba X-ray Tube |
1set |
4 |
Electric multi-leaf collimator |
1 set |
5 |
Diagnostic Bed |
1set |
6 |
Thales Three Field image intensifier |
1set |
7 |
CCD Camera |
1set |
8 |
Medical HD monitor |
1set |
9 |
High voltage cable |
2sets |
10 |
workstation |
1set |
3. Main Specifications of Radiography & Fluoroscopy Digital X ray machine System |
Item |
Content |
Technical parameter |
Power supply |
Voltage |
380V±38V |
Frequency |
50Hz±1Hz |
Capacity |
≥65kVA |
internal resistor |
≤0.17Ω |
Digital X-ray high voltage system (import high-frequency generator) |
photography |
Power Output |
50KW |
Inverter Frequency |
200KHZ |
Tube Voltage |
40kv-150kv step regulation |
Tube Current |
10mA-630mA step regulation |
Exposure time |
1.0s-6300ms step regulation |
Control interface |
Touched LCD |
Control hand |
One-button operation handle |
fluoroscopy |
Tube Voltage |
40kv-120kv continuous regulation |
Tube Current |
0.5mA-6mA continuous regulation |
Digital Controlled X-ray Tube |
Tube Brand |
Toshiba |
Tube Focus: Large Focus/Small Focus |
1.2mm /0.6mm |
Input Power |
Large focus: 50kW small focus: 19kW |
thermal capacity |
300 KHU |
Rotary anode speed |
3000rpm |
Micro-computer control remote diagnostic table |
Material of the tabletop |
high strength, low absorb carbon fiber |
Rotation of the table |
90°~0°~-25° |
Transverse travel of table |
±110mm |
Longitudinal travel of the photography holder and film spot device |
≥720mm |
X-ray Focus-film gauge |
1100 mm-1500 mm |
Rotating foot plate |
±360° rotation |
Full film photography size |
8inch×1inch-14inch×17inch |
Compressor force |
80N-130N |
Dividing method for spot film |
Full film, half dividing, three parts dividing, four parts dividing |
Control method for diagnostic table |
Remote, table control, frequency conversion soft starting and stopping |
beam limiter |
Electric Multi-leaf |
fixed bucky device for table |
Grid density: 103L/INCH, Grid ratio: 10:1, focusing distance: 120cm, fixed type: 15inch×18inch |
Intensifier and CRT Monitor |
Image Intensifier |
Toshiba (9inch/6inch/4.5inch) Image Intensifier |
high resolution CCD (digital cameras) |
ultra-low-light, standard 1000,000 pixel |
Monitor (Optional) |
14inch medical high-definition monitor, horizontal central resolution ratio :1000 lines, fringe: 800 lines, video bandwidth: 12.5MHz ,50bit, image number/second: 25 frame |
workstation |
i5-6500(3.20 GHz),4 GB DDR3, 500GB SATA (7200 rpm), work list; DSI function; Gather and deal with image; Spot Film Acquire Image; Image Playback; Rich Image Processing Function; X-ray Film Printer Function: Report Edit and Print Function; |
LCD colorful screen |
19" LED Medical Use High-Definition Monitor |