| Customization: | Available |
|---|---|
| Classification: | Imaging Diagnostic Equipment |
| Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| 2. Standard Configuration of Radiography & Fluoroscopy Digital X ray machine System | |||
| No. | Item | Quantity | |
| 1 | Remote console (with touch screen control) | 1 set | |
| 2 | high-voltage generator | 1 set | |
| 3 | Toshiba X-ray Tube | 1set | |
| 4 | Electric multi-leaf collimator | 1 set | |
| 5 | Diagnostic Bed | 1set | |
| 6 | Thales Three Field image intensifier | 1set | |
| 7 | CCD Camera | 1set | |
| 8 | Medical HD monitor | 1set | |
| 9 | High voltage cable | 2sets | |
| 10 | workstation | 1set | |
| 3. Main Specifications of Radiography & Fluoroscopy Digital X ray machine System | |||
| Item | Content | Technical parameter | |
| Power supply | Voltage | 380V±38V | |
| Frequency | 50Hz±1Hz | ||
| Capacity | ≥65kVA | ||
| internal resistor | ≤0.17Ω | ||
| Digital X-ray high voltage system (import high-frequency generator) | photography | Power Output | 50KW |
| Inverter Frequency | 200KHZ | ||
| Tube Voltage | 40kv-150kv step regulation | ||
| Tube Current | 10mA-630mA step regulation | ||
| Exposure time | 1.0s-6300ms step regulation | ||
| Control interface | Touched LCD | ||
| Control hand | One-button operation handle | ||
| fluoroscopy | Tube Voltage | 40kv-120kv continuous regulation | |
| Tube Current | 0.5mA-6mA continuous regulation | ||
| Digital Controlled X-ray Tube | Tube Brand | Toshiba | |
| Tube Focus: Large Focus/Small Focus | 1.2mm /0.6mm | ||
| Input Power | Large focus: 50kW small focus: 19kW | ||
| thermal capacity | 300 KHU | ||
| Rotary anode speed | 3000rpm | ||
| Micro-computer control remote diagnostic table | Material of the tabletop | high strength, low absorb carbon fiber | |
| Rotation of the table | 90°~0°~-25° | ||
| Transverse travel of table | ±110mm | ||
| Longitudinal travel of the photography holder and film spot device | ≥720mm | ||
| X-ray Focus-film gauge | 1100 mm-1500 mm | ||
| Rotating foot plate | ±360° rotation | ||
| Full film photography size | 8inch×1inch-14inch×17inch | ||
| Compressor force | 80N-130N | ||
| Dividing method for spot film | Full film, half dividing, three parts dividing, four parts dividing | ||
| Control method for diagnostic table | Remote, table control, frequency conversion soft starting and stopping | ||
| beam limiter | Electric Multi-leaf | ||
| fixed bucky device for table | Grid density: 103L/INCH, Grid ratio: 10:1, focusing distance: 120cm, fixed type: 15inch×18inch | ||
| Intensifier and CRT Monitor | Image Intensifier | Toshiba (9inch/6inch/4.5inch) Image Intensifier | |
| high resolution CCD (digital cameras) | ultra-low-light, standard 1000,000 pixel | ||
| Monitor (Optional) | 14inch medical high-definition monitor, horizontal central resolution ratio :1000 lines, fringe: 800 lines, video bandwidth: 12.5MHz ,50bit, image number/second: 25 frame | ||
| workstation | i5-6500(3.20 GHz),4 GB DDR3, 500GB SATA (7200 rpm), work list; DSI function; Gather and deal with image; Spot Film Acquire Image; Image Playback; Rich Image Processing Function; X-ray Film Printer Function: Report Edit and Print Function; | ||