Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
2. Standard Configuration of Radiography & Fluoroscopy Digital X ray machine System | |||
No. | Item | Quantity | |
1 | Remote console (with touch screen control) | 1 set | |
2 | high-voltage generator | 1 set | |
3 | Toshiba X-ray Tube | 1set | |
4 | Electric multi-leaf collimator | 1 set | |
5 | Diagnostic Bed | 1set | |
6 | Thales Three Field image intensifier | 1set | |
7 | CCD Camera | 1set | |
8 | Medical HD monitor | 1set | |
9 | High voltage cable | 2sets | |
10 | workstation | 1set | |
3. Main Specifications of Radiography & Fluoroscopy Digital X ray machine System | |||
Item | Content | Technical parameter | |
Power supply | Voltage | 380V±38V | |
Frequency | 50Hz±1Hz | ||
Capacity | ≥65kVA | ||
internal resistor | ≤0.17Ω | ||
Digital X-ray high voltage system (import high-frequency generator) | photography | Power Output | 50KW |
Inverter Frequency | 200KHZ | ||
Tube Voltage | 40kv-150kv step regulation | ||
Tube Current | 10mA-630mA step regulation | ||
Exposure time | 1.0s-6300ms step regulation | ||
Control interface | Touched LCD | ||
Control hand | One-button operation handle | ||
fluoroscopy | Tube Voltage | 40kv-120kv continuous regulation | |
Tube Current | 0.5mA-6mA continuous regulation | ||
Digital Controlled X-ray Tube | Tube Brand | Toshiba | |
Tube Focus: Large Focus/Small Focus | 1.2mm /0.6mm | ||
Input Power | Large focus: 50kW small focus: 19kW | ||
thermal capacity | 300 KHU | ||
Rotary anode speed | 3000rpm | ||
Micro-computer control remote diagnostic table | Material of the tabletop | high strength, low absorb carbon fiber | |
Rotation of the table | 90°~0°~-25° | ||
Transverse travel of table | ±110mm | ||
Longitudinal travel of the photography holder and film spot device | ≥720mm | ||
X-ray Focus-film gauge | 1100 mm-1500 mm | ||
Rotating foot plate | ±360° rotation | ||
Full film photography size | 8inch×1inch-14inch×17inch | ||
Compressor force | 80N-130N | ||
Dividing method for spot film | Full film, half dividing, three parts dividing, four parts dividing | ||
Control method for diagnostic table | Remote, table control, frequency conversion soft starting and stopping | ||
beam limiter | Electric Multi-leaf | ||
fixed bucky device for table | Grid density: 103L/INCH, Grid ratio: 10:1, focusing distance: 120cm, fixed type: 15inch×18inch | ||
Intensifier and CRT Monitor | Image Intensifier | Toshiba (9inch/6inch/4.5inch) Image Intensifier | |
high resolution CCD (digital cameras) | ultra-low-light, standard 1000,000 pixel | ||
Monitor (Optional) | 14inch medical high-definition monitor, horizontal central resolution ratio :1000 lines, fringe: 800 lines, video bandwidth: 12.5MHz ,50bit, image number/second: 25 frame | ||
workstation | i5-6500(3.20 GHz),4 GB DDR3, 500GB SATA (7200 rpm), work list; DSI function; Gather and deal with image; Spot Film Acquire Image; Image Playback; Rich Image Processing Function; X-ray Film Printer Function: Report Edit and Print Function; | ||
LCD colorful screen | 19" LED Medical Use High-Definition Monitor |