Customization: | Available |
---|---|
Type: | Anaesthesia Machine |
Kind: | All |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Main body | High-strength engineering plastic rack, light,beautiful and corrosion resistant |
2.Scope of application | Adult, Child |
3.Gas source | O2, N2O: 0.27~0.55MPa ; N2O: 0.27~0.55MPa |
4.Flow meter | O2: 0.1~1.0L/min 1.1~10L/min; N20: 0.1~1.0L/min 1.1~10L/min; Air: 0.1~10L/min |
5.O2, N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%;When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. |
6.Flow rate of rapid oxygen supply | 25~75L/min |
7.Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
8.Vaporizer | It has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%. |
9.Respiratory circuit | Working mode: all-close, semi-close, semi-open |
APL: 0.5~7 kPa | |
10.Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1500 ml; bellows for children, tidal volume range:0~300 ml anyone can be chosen for application as required by the customer |
1.Display mode | High-definition 8.4" TFT color LCD screen display | ||
2.Ventilation mode | IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate) | ||
3.Ventilation parameters | Tidal volume 20~1500ml | ||
Rate 1~99 bpm | |||
SIMV rate 2~20 bpm | |||
I:E 4:1~1:8 | |||
Inspiratory trigger pressure -1.0~2.0 kPa | |||
PEEP 0~2.0 kPa | |||
Pressure range 1.0~6.0 kPa | |||
SIGH 1.5 times the inspiratory time (70-150 adjustable) | |||
Inspiratory platform 0~50% | |||
4.Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform,PEEP,inspiratory trigger pressure. | ||
5.Monitoring of oxygen concentration | 21%~100% | ||
6.Security Alarm System |
Airway Pressure alarm | upper limit setting range | 1.0~6.0kPa |
low limit setting range | 0.2~5.0kPa | ||
Oxygen Concentration alarm | upper limit setting range | 21%-100% | |
low limit setting range | 10%-80% | ||
Per-minute ventilation volume alarm | upper limit setting range | 3.0~30L/min | |
low limit setting range | 1.0~10L/min | ||
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa | ||
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 second. | ||
Power alarm | |||
7.Power | AC 220V±10% 50Hz±1Hz | ||
8.Mechanical Arms | Yes |